Order recell kits at www.stakemill.com We use SANYO batteries, these are the kits we supply to repair facilities around the world to rebuild survey instrument batteries. Buy direct and do the work yourself, some knowledge required for install, verify your unit is servicable prior to ordering. We offer kits for Leica, Nikon, Pentax, Sokkia and Topcon Survey and GPS Instruments.
Survey Battery Recell Kits at STAKEMILL
August 18, 2011Nikon Premier Prism Assembly H06E64021
December 20, 2008Nikon Premier Prism Assembly H06E64021
64021 Premier Prism Assembly – waterproof canister type prism, anodized aluminum tilting holder with simple locking system.

Nikon Premier Prism Assembly H06E64020
December 20, 2008Nikon Premier Prism Assembly H06E64020
64020 Premier Prism Assembly – waterproof canister type prism, anodized aluminum tilting holder with locking clamp screw.

Nikon SVR Series® Grade Rods SVR
December 20, 2008NEW STYLE SVR Series Leveling Rods 
Our SVR Series Leveling Rods have a rectangular-oval shape, flat on the front and back with round corners. This convenient shape prevents the scale from rolling, making observation much easier. The rods are also water-proof, corrosion-resistant, and non-conductive.
The SVR Series rods have a measuring scale on the back (with the exception of the two-scaled rods) that allow the user to read overall height measurements at eye level, which is useful in making clearance and height measurements. Also on the back-side with the measuring scale, there are alternate 1’ red and white markings that are suitable for stadia purposes.
The newly redesigned locking mechanism now features round buttons. Tight and accurate, the lock is specifically designed to resist jamming from sand and dirt.
Disassembly is quick and easy. Simply press the lock buttons and pull the sections out. To further disassemble, a Phillips screwdriver is needed.
The thread in the top section of the SVR is ¼ x 20”, but can be adapted to 5/8 x 11 by purchasing an adapter.
Brackets are needed to attach laser sensors to the SVR Series.
Reading the Measuring Scale: To read the measuring scale on the USL, the height measurement is read at the top of the base section. To read the measuring scale on the New and Original SVR, the height measurement is read at the top of the first unextended section.
USL Series
SVR Series
16’ and 25’ Models Available
16’ and 25’ Models Available
All sections collapse inside base
All sections stack on top of each other
Collapsed Lengths:
USL-25’ 59 5/8”
USL-16’ 56 ½”
Collapsed Lengths:
SVR-25′ (NEW) 58 ½”
SVR-25’ (Original) 66 ¼”
SVR-16’ 59 ¼”
Model Graduations
USL Series
Feet, Tenths, Hundredths
Feet, Inches, Eighths
Meters, Decimeters, Centimeters (“E” metric scale only metric scale available on the USL Series)
SVR Series
Feet, Tenths, Hundredths
Feet, Inches, Eighths
Meters, Decimeters, Centimeters (“E” metric)
Meters, Decimeters, Centimeters, 0.5 Centimeters (0.5
Centimeter and Philly Metric Models)
Two-Scaled SVR Series (two leveling scales and no measuring scale)
Tenths, Inches
Tenths, Philly Metric
For older models, stacking kits are available for the USL to make the sections stack like the SVR. NOTE: If the stacking kit is installed on an USL, the measuring scale on the back-side becomes inoperable. SVR and USL sections are not interchangeable.
To read the measuring scale on the USL, the height measurement is read at the top of the base section. To read the measuring scale on the SVR, the height measurement is read at the top of the first unextended section.
Our SVR Series Leveling Rods have a rectangular-oval shape, flat on the front and back with round corners. This convenient shape prevents the scale from rolling, making observation much easier. The rods are also water-proof, corrosion-resistant, and non-conductive.
The SVR Series rods have a measuring scale on the back (with the exception of the two-scaled rods) that allow the user to read overall height measurements at eye level, which is useful in making clearance and height measurements. Also on the back-side with the measuring scale, there are alternate 1’ red and white markings that are suitable for stadia purposes.
The newly redesigned locking mechanism now features round buttons. Tight and accurate, the lock is specifically designed to resist jamming from sand and dirt.
Disassembly is quick and easy. Simply press the lock buttons and pull the sections out. To further disassemble, a Phillips screwdriver is needed.
The thread in the top section of the SVR is ¼ x 20”, but can be adapted to 5/8 x 11 by purchasing an adapter.
Brackets are needed to attach laser sensors to the SVR Series.
Reading the Measuring Scale: To read the measuring scale on the USL, the height measurement is read at the top of the base section. To read the measuring scale on the New and Original SVR, the height measurement is read at the top of the first unextended section.
USL Series
SVR Series
16’ and 25’ Models Available
16’ and 25’ Models Available
All sections collapse inside base
All sections stack on top of each other
Collapsed Lengths:
USL-25’ 59 5/8”
USL-16’ 56 ½”
Collapsed Lengths:
SVR-25′ (NEW) 58 ½”
SVR-25’ (Original) 66 ¼”
SVR-16’ 59 ¼”
Model Graduations
USL Series
Feet, Tenths, Hundredths
Feet, Inches, Eighths
Meters, Decimeters, Centimeters (“E” metric scale only metric scale available on the USL Series)
SVR Series
Feet, Tenths, Hundredths
Feet, Inches, Eighths
Meters, Decimeters, Centimeters (“E” metric)
Meters, Decimeters, Centimeters, 0.5 Centimeters (0.5
Centimeter and Philly Metric Models)
Two-Scaled SVR Series (two leveling scales and no measuring scale)
Tenths, Inches
Tenths, Philly Metric
For older models, stacking kits are available for the USL to make the sections stack like the SVR. NOTE: If the stacking kit is installed on an USL, the measuring scale on the back-side becomes inoperable. SVR and USL sections are not interchangeable.
Sokkia Item # 099362 25′ SVR 10ths
SVR old part numbers 90340 90341 90302 90346
SVR new part numbers 98010

Posted by Stakemill 